Skip to content

Dew point calculator relative humidity

Enter the air temperature and the dew point to get relative humidity, vapour pressure and the dew point spread. It works in °C and °F and uses the same Buck equation that weather services use, so the result matches a forecast or a hygrometer to a tenth of a percent.

Find relative humidity

Move a slider or type a value. Results and the chart update as you go.

°C
°C

How dew point calculator relative humidity works?

To calculate relative humidity (RH) from dew point, the calculator divides the vapour pressure at the dew point by the saturation vapour pressure at the air temperature and multiplies by 100. At 25 °C (77 °F) air with a 15 °C (59 °F) dew point, the result is 54% RH.

  1. It finds the saturation vapour pressure at the air temperature: the most water vapour the air could hold.
  2. It finds the saturation vapour pressure at the dew point. That equals the vapour actually in the air.
  3. It divides the second by the first and multiplies by 100. That ratio is the relative humidity.
  4. The gauge places the result on a dry-to-very-humid scale so you can read it at a glance.

Dew point calculator relative humidity formula

The relative humidity formula is RH = 100 × e(Td) ÷ es(T). Both vapour pressures come from the Arden Buck equation, es = 6.1121 × exp[(18.678 − T/234.5) × T ÷ (257.14 + T)] in hectopascals (hPa). The worked example below uses the values in the calculator.

Dew point calculator relative humidity conversion chart

Find the air temperature on the left and the dew point across the top. The cell is the relative humidity. A dash means the dew point would be above the air temperature, which can't happen.

Relative humidity chart from dew point: Relative humidity (%) by air temperature and dew point (°C)
Air tempTd 0 °CTd 5 °CTd 10 °CTd 15 °CTd 20 °CTd 25 °C
5 °C70100————
10 °C5071100———
15 °C365172100——
20 °C26375373100—
25 °C1928395474100
30 °C142129405575
35 °C111622304256

Dew point vs relative humidity: what each number tells you

Relative humidity (RH) and dew point both describe moisture, but they answer different questions. Dew point is an absolute measure: the temperature the air would have to cool to before water condenses. Relative humidity is a ratio: how much water vapour the air holds compared with the most it could hold at its current temperature.

Because warm air can hold far more water than cool air, RH changes all day while the dew point barely moves. A summer morning at 18 °C with a 16 °C dew point shows 88% RH; by mid-afternoon at 30 °C, the same air reads only 43%. The dew point stayed at 16 °C, which is why the afternoon still feels sticky.

How to calculate relative humidity from dew point

  1. Calculate the actual vapour pressure from the dew point: e = es(Td).
  2. Calculate the saturation vapour pressure from the air temperature: es(T).
  3. Divide and multiply by 100: RH = 100 × e ÷ es.

Worked example at 25 °C air with a 15 °C dew point: e = 17.05 hPa, es = 31.69 hPa, so RH = 100 × 17.05 ÷ 31.69 = 53.8%.

Relative humidity formula and the quick rule

The calculator uses the Buck (1996) equation for saturation vapour pressure, es(T) = 6.1121 × exp[(18.678 − T/234.5) × T ÷ (257.14 + T)] hPa. With the Magnus approximation the whole thing simplifies to:

RH = 100 × exp(17.625·Td ÷ (243.04 + Td)) ÷ exp(17.625·T ÷ (243.04 + T))

For a mental estimate, use RH ≈ 100 − 5 × (T − Td) in °C. It’s within a few points above 50% RH and gets worse in dry air.

Relative humidity vs dew point compared

Relative humidity Dew point
What it measures Saturation ratio (%) Condensation temperature
Changes when air warms or cools Yes, a lot No
Best for Drying, storage, sensors, mold limits Comfort, fog, condensation, weather
Same value means same mugginess? No Yes
Typical comfortable range 30–60% indoors 10–16 °C (50–60 °F)

RH from dew point: quick reference

Spread T − Td RH at 10 °C RH at 20 °C RH at 30 °C
0 °C 100% 100% 100%
2 °C 87% 88% 89%
4 °C 76% 78% 79%
6 °C 66% 68% 70%
8 °C 57% 60% 62%
10 °C 50% 53% 55%
15 °C 34% 37% 40%
20 °C 23% 26% 29%

When to use this calculator

Situation Why RH from dew point helps
Reading a weather report Forecasts list dew point; convert it to RH for a hygrometer or plant care
Indoor air and HVAC Check if a room’s dew point keeps RH in the 30–60% band
Storage and museums Archives specify RH; dew point stays stable when rooms are heated
Greenhouses Combine RH with temperature to manage disease risk and vapour pressure deficit

Dew point calculator relative humidity FAQs

How do you calculate relative humidity from dew point?

Find the vapour pressure at the dew point and the saturation vapour pressure at the air temperature, then divide: RH = 100 × e(Td) ÷ es(T). At 25 °C with a 15 °C dew point that gives 54%.

Is dew point or relative humidity better for measuring humidity?

Dew point tells you how much water is actually in the air, and it barely changes during the day. Relative humidity tells you how close the air is to saturation, and it swings with temperature. Use dew point for comfort and condensation, RH for drying, storage and sensors.

Does dew point change with relative humidity?

No, not directly. If the moisture in the air stays the same, warming or cooling the air changes RH but leaves the dew point where it is. The dew point only moves when water vapour is added or removed.

What relative humidity is a 60 °F dew point?

It depends on the air temperature. A 60 °F dew point is 71% RH at 70 °F, 51% at 80 °F and 37% at 90 °F.

Can relative humidity be 100% without rain?

Yes. At 100% RH the air temperature equals the dew point, which usually means fog, mist or dew rather than rain. Rain needs droplets to grow large enough to fall.

Why is relative humidity highest in the early morning?

The air is coolest just before sunrise while the dew point stays almost constant, so the gap between them is smallest and RH peaks. As the air warms, RH falls even though the moisture hasn't changed.

What is a quick way to estimate RH from dew point?

Above about 50% RH, each 1 °C of spread between temperature and dew point lowers RH by roughly 5 points: RH ≈ 100 − 5 × (T − Td). At a 4 °C spread that's about 80%; the exact value at 20 °C is 78%.

What RH is comfortable indoors?

Most guidance, including ASHRAE and the US EPA, recommends keeping indoor relative humidity between about 30% and 60%. In a 20–22 °C room that matches a dew point of roughly 2–14 °C.

Can I use this calculator with Fahrenheit?

Yes. Switch the units to °F; the calculation converts to Celsius internally and back, so the result is identical.

What is the formula for relative humidity from dew point?

The formula is RH = 100 × es(Td) ÷ es(T), where es is the saturation vapour pressure from the Buck or Magnus equation.

What relative humidity is a dew point of 20 °C at 30 °C?

A 20 °C (68 °F) dew point at 30 °C (86 °F) is 55% relative humidity.

Can relative humidity be above 100%?

No, relative humidity stays at or below 100% in normal air. Brief supersaturation of a fraction of a percent occurs inside clouds before droplets form.