Dew point calculator relative humidity
Calculate relative humidity from temperature and dew point, or dew point from RH.
Open calculatorEnter any two of air temperature, relative humidity and dew point to get the third. The result, chart and gauges update as you type.
Fill in any two values. The third is calculated.
Solve for
The dry-bulb temperature of the air, read from an ordinary thermometer shielded from sun and radiation.
How much water vapour the air holds compared with the most it could hold at that temperature. Use a value above 0% and up to 100%.
The temperature the air must be cooled to, at constant pressure and moisture, before water vapour starts to condense. It can never be higher than the air temperature.
Most accurate from −45 to 60 °C (−49 to 140 °F). Dew point is calculated over liquid water. Below 0 °C the frost point is shown as well.
Cool the air without adding or removing moisture and it moves left until it meets the 100% curve. That temperature is the dew point. Drag the dot or click anywhere on the chart to change the air; hover to read any point.
Dew point tracks comfort better than relative humidity does.
Will a window, pipe or wall at this temperature collect water?
Type into any moisture field and the others follow: atmospheric dew point, ppm, absolute humidity, lb/MMSCF or the dew point at line pressure.
Dewpoint values
Optional inputs
Pick a gas of known molecular weight, or choose the last option to type a custom value. Molecular weight only affects ppm by weight.
Below 0 °C, report
ISO 8573-1 water vapour classes for compressed air, by pressure dew point. Shaded classes are met; the solid one is the best class met.
Absolute values
g/m³ is per normal cubic metre (0 °C, 1.01325 bar). lb/MMSCF is per million standard cubic feet (60 °F, 14.696 psia).
Same moisture content, compressed further. Bands show the ISO 8573-1 classes.
The calculator turns temperature and humidity into a vapour pressure, then finds the temperature at which that vapour pressure saturates the air. The same equation runs in every direction, so dew point, humidity and air temperature always agree. Every chart and gauge on the page redraws from the result as you type.
Shaw Moisture Meters publishes a free online calculator for pressure dew point and moisture content (source). Its guide runs in this order (source):
The trace moisture section of the tool follows the same layout. Shaw's worked example converts −40 °C at atmospheric pressure to about −17.7 °C at 10 bar(A). This calculator gives −18.2 °C for the same case. The half-degree gap comes from reporting a frost point over ice and correcting for gas pressure (see Method and Sources).
Shaw supplies a pocket pressure dewpoint calculator with its dew point meters, hygrometers and trace moisture analysers (source). It is a set of three rotating parts, with a base wheel for trace moisture content and a centre wheel for pressure. The front shows the dew point at any pressure; the back holds a conversion table (source).
The wheel is handy on site. The online version gives more decimal places and covers more units.
The trace moisture section of the tool handles dry gases, where the dew point sits far below room temperature and the gas is under pressure. Type into any moisture field and the rest follow. The field you typed in is marked Input.
The gas only changes ppm by weight, through its molecular weight. Dew point, ppm(v), g/m³ and lb/MMSCF stay the same for any gas.
| Gas | Molecular weight (g/mol) | In the menu |
|---|---|---|
| Air | 29 | Yes |
| Nitrogen | 28 | Yes |
| Argon | 40 | Yes |
| Oxygen | 32 | Yes |
| Hydrogen | 2 | Yes |
| Carbon dioxide | 44 | Yes |
| Sulfur hexafluoride (SF₆) | 146 | Yes |
| Helium | 4 | Enter as a custom gas |
| Natural gas | about 16 to 20, from your gas analysis | Enter as a custom gas |
For helium or natural gas, choose Gas of known molecular weight and type the value.
Enter the dew point at atmospheric pressure in °C or °F. Most portable hygrometers sample at atmospheric pressure, so this is the reading you usually have. Below 0 °C, choose whether to report a frost point (over ice, the usual choice for compressed air) or a dew point over supercooled water.
The pressure dew point is the dew point of the gas at line pressure. Compressing a gas squeezes its water vapour into a smaller volume, so the dew point rises. Air at −40 °C at atmospheric pressure has a pressure dew point of about −20.5 °C at 7 barg. The result card shows which ISO 8573-1 compressed air class the reading meets, and the chart plots the dew point against pressure.
Find your air temperature on the left, read across to your relative humidity, and the cell gives the dew point, rounded to the nearest degree.
Hover a cell to trace its row and column. Click a cell to load it into the calculator.
| Air temp | 30% | 40% | 50% | 60% | 70% | 80% | 90% |
|---|---|---|---|---|---|---|---|
| 10 °C | −7 | −3 | 0 | 3 | 5 | 7 | 8 |
| 15 °C | −2 | 2 | 5 | 7 | 10 | 12 | 13 |
| 20 °C | 2 | 6 | 9 | 12 | 14 | 16 | 18 |
| 25 °C | 6 | 10 | 14 | 17 | 19 | 21 | 23 |
| 30 °C | 11 | 15 | 18 | 21 | 24 | 26 | 28 |
| 35 °C | 15 | 19 | 23 | 26 | 29 | 31 | 33 |
| Air temp | 30% | 40% | 50% | 60% | 70% | 80% | 90% |
|---|---|---|---|---|---|---|---|
| 50 °F | 20 | 27 | 32 | 37 | 41 | 44 | 47 |
| 60 °F | 29 | 36 | 41 | 46 | 50 | 54 | 57 |
| 70 °F | 37 | 45 | 51 | 55 | 60 | 64 | 67 |
| 80 °F | 46 | 54 | 60 | 65 | 69 | 73 | 77 |
| 90 °F | 54 | 62 | 69 | 74 | 79 | 83 | 87 |
| 100 °F | 63 | 71 | 78 | 84 | 88 | 93 | 97 |
At 100% humidity the dew point equals the air temperature. At the same humidity, warmer air has a much higher dew point: 50% at 10 °C gives 0 °C, but 50% at 35 °C gives 23 °C.
This free online dew point calculator tells you the temperature at which air starts to form water droplets. Enter the air temperature and relative humidity to calculate dew point in Celsius or Fahrenheit, or give it any two of the three values and it works out the third. It doubles as a dew point temperature calculator and a relative humidity calculator, with every step of the dew point formula shown.
The dew point is the most direct measure of how much water vapour the air holds. Relative humidity rises and falls as the air warms and cools through the day. The dew point stays put unless moisture is added or taken away. So it is the better guide to comfort, fog, frost and condensation.
People use a dew point calculator to:
The calculator has two parts. The air calculator above takes temperature, relative humidity and dew point, shows vapour pressure and absolute humidity, and draws the cooling path on a chart. The trace moisture calculator converts a dew point between atmospheric and line pressure, and into ppm(v), ppm(w), g/m³ and lb/MMSCF for air, nitrogen, argon and other gases.
The input panel is where you calculate dew point online. It has three fields: air temperature in °C, °F or K; relative humidity in %, above 0 and up to 100; and dew point in °C, °F or K.
Pick what to solve for with the Solve for switch. The field being solved turns blue and shows Calculated. Type into it and the calculator switches to solving the field you touched least recently. Tick Show vapour pressure and absolute humidity to add vapour pressure, saturation vapour pressure, absolute humidity and mixing ratio to the result. Below 0 °C the frost point appears as well.
Each field has a pin to save its value for your next visit, and a menu to copy, reset or clear it. The calculator is most accurate from −45 to 60 °C (−49 to 140 °F).
The dew point is the temperature air must cool to, at constant pressure and moisture, before its water vapour starts to condense into liquid. Cool a parcel of air below its dew point and the extra vapour turns into dew, fog or cloud. Below 0 °C (32 °F) the vapour can turn straight into ice; that temperature is the frost point.
The National Weather Service puts it simply: the dew point is the temperature the air needs to be cooled to, at constant pressure, to reach 100% relative humidity. Weather stations measure it with a hygrometer, or calculate it from temperature and humidity exactly as this dew point calculator does.
The significance of dew point is that it tracks the actual amount of water in the air. A dew point of 20 °C means the same moisture whether the afternoon is 25 °C or 35 °C. That is why forecasters use it for comfort, fog and frost.
Relative humidity
Humidity is the amount of water vapour in the air. It can be given as a mass per volume (absolute humidity, in g/m³), a mass per mass (mixing ratio, in g/kg), a partial pressure (vapour pressure, in hPa) or a temperature (the dew point). All four describe the same thing.
Relative humidity (RH) compares the vapour in the air with the most the air could hold at its current temperature. Warm air can hold far more vapour than cold air. So the same moisture gives a low RH in the afternoon and a high RH at dawn. RH reaches 100% when the air temperature falls to the dew point.
Can dew point be calculated? Yes. You need the air temperature (T, in °C) and relative humidity (RH, in %). The Magnus formula gives a close answer in two steps, with the Alduchov and Eskridge constants a = 17.625 and b = 243.04 °C. Step 1: γ = ln(RH/100) + a·T/(b + T). Step 2: Td = b·γ/(a − γ). Try it with your own numbers:
To calculate dew point in Fahrenheit, convert to Celsius first with °C = (°F − 32) × 5/9, run the formula, then convert back with °F = °C × 9/5 + 32.
This dew point calculator solves the more exact Buck (1996) vapour pressure equation instead. Between −40 and 50 °C the two agree to about 0.1 °C.
You can use dew point to calculate relative humidity. Divide the saturation vapour pressure at the dew point by the saturation vapour pressure at the air temperature: RH = 100 × exp(a·Td/(b + Td)) ÷ exp(a·T/(b + T)).
In the calculator, set Solve for to Humidity, then enter the air temperature and dew point. At a fixed air temperature, a higher dew point always means a higher relative humidity.
You can find dew point in your head with a rule of thumb: subtract one fifth of the "missing" humidity from the temperature. At 70% RH, for example, 30 points are missing, so subtract 6 °C. In symbols, Td ≈ T − (100 − RH) ÷ 5, with T in °C. It works well above about 50% RH and drifts in dry air, where the full dew point equation is needed.
| Relative humidity | Rule-of-thumb estimate at 25 °C | Exact dew point at 25 °C |
|---|---|---|
| 100% | 25 °C | 25.0 °C |
| 90% | 23 °C | 23.2 °C |
| 80% | 21 °C | 21.3 °C |
| 70% | 19 °C | 19.1 °C |
| 60% | 17 °C | 16.7 °C |
| 50% | 15 °C | 13.9 °C |
Every dew point formula starts from the Clausius–Clapeyron relation, the piece of thermodynamics that says saturation vapour pressure rises roughly exponentially with temperature. In 1844 the German physicist Heinrich Gustav Magnus fitted measured vapour pressures with an exponential curve, and the Magnus formula (also called Magnus–Tetens) is still the standard way to calculate dew point by hand. Arden Buck refined the fit in 1981 and 1996; the Buck equation is what this calculator solves. For reference work, the World Meteorological Organization's instrument guide uses Magnus-type constants from Sonntag (1990), and IAPWS publishes the international reference formulation for the properties of water.
| Equation | Year | Typical accuracy | Used for |
|---|---|---|---|
| Simple rule: T − (100 − RH)/5 | 2005 (Lawrence) | ±1 °C above 50% RH | Mental estimates |
| Magnus (17.625, 243.04) | 1844 / 1996 | ±0.1–0.2 °C, −40 to 50 °C | Most online calculators, spreadsheets |
| Sonntag (17.62, 243.12) | 1990 | Similar to Magnus | WMO instrument guide |
| Arden Buck equation | 1981 / 1996 | About 0.05% in vapour pressure | This calculator, instruments |
| IAPWS formulations | 1995 onward | Reference standard | Metrology, steam tables |
Most wrong answers come from a handful of slips. Check these before trusting a result from a spreadsheet or a handheld meter.
| Mistake | What goes wrong | Fix |
|---|---|---|
| Putting °F into the Magnus formula | The constants are for Celsius; the answer is nonsense | Convert to °C first, then back |
| Using RH as 60 instead of 0.60 | ln(60) instead of ln(0.60) shifts the result by tens of degrees | Divide RH by 100 inside the logarithm |
| Mixing up dew point and frost point | Below 0 °C they differ by up to several degrees | State which one; frost point for ice |
| Ignoring pressure | Compressed gas has a much higher dew point than the vented sample | Quote pressure dew point at line pressure |
| Reading a sensor in the sun or straight after moving it | Temperature error feeds straight into the dew point | Shade the sensor and let it settle |
| Trusting more decimals than the sensor has | ±2–3% RH is roughly ±0.5 °C of dew point | Round to 0.5 °C for weather use |
| Conditions | Result | What it means | Try |
|---|---|---|---|
| 25 °C, 60% RH | Dew point 16.7 °C | Pleasant, a little moisture in the air | |
| 86 °F, 70% RH | Dew point 75.1 °F | Oppressive; sweat barely dries | |
| −5 °C, 80% RH | Dew point −7.9 °C, frost point −7.0 °C | Frost forms on surfaces below −7 °C | |
| 30 °C, dew point 20 °C | RH 55.1% | Humid but not saturated |
Press Try it to load any row into the calculator. Worked through, the first example runs like this. γ = ln(0.60) + 17.625 × 25 / (243.04 + 25) = −0.511 + 1.644 = 1.133. Then Td = 243.04 × 1.133 / (17.625 − 1.133) = 16.7 °C.
Dew point and frost point. Below 0 °C, water vapour can deposit straight onto surfaces as ice, so the temperature that matters is the frost point. It is always a little warmer than the dew point for the same air, because ice holds less vapour than supercooled water. The calculator shows both whenever the dew point is below freezing; the Dew point frost point calculator goes further.
The result card shows the solved value in large type, with the other units underneath. Then come four things to look at:
The cooling-path chart plots vapour pressure against temperature. The orange dot is your air. Follow the dashed line left at constant moisture until it meets the blue 100% curve: that meeting point is the dew point.
The condensation check uses the same result. Slide the surface temperature down. When it drops to the dew point or below, the pane fogs and the status turns red.
Relative humidity tells you how close the air is to saturation. Dew point tells you how much water is actually there. The difference matters when temperatures change.
| Dew point | Relative humidity | |
|---|---|---|
| Measures | Actual moisture, as a temperature | Moisture compared with the maximum possible |
| Changes as the day warms | Barely | Drops |
| Good for | Comfort, fog, frost, condensation, gas dryness | Mold growth, drying, static, storage |
| Same air at dawn and afternoon | 15 °C both times | 94% at 16 °C, 45% at 28 °C |
Is dew point more important than humidity? For comfort, yes. A cool morning at 90% RH can feel fresh, while a hot afternoon at 50% RH feels sticky. The dew point catches that; RH does not.
Does dew point change with relative humidity? Only if the moisture changes. At a fixed air temperature, more moisture raises both the dew point and RH together. When the temperature alone changes, RH moves and the dew point stays the same. Use this calculator as a dew point vs humidity calculator: fix the dew point, change the air temperature, and watch RH move.
What happens when the dew point is reached? The air is saturated, and any extra cooling squeezes water out of it. On a clear night, grass, car roofs and leaves lose heat to the sky faster than the air around them. Once their surfaces drop to the dew point, vapour condenses on them as droplets. That is morning dew. If the surface is below 0 °C and below the frost point, you get frost instead.
Most people feel comfortable with a dew point between 10 and 16 °C (50 to 60 °F). Above that, sweat dries more slowly and the air feels sticky. This dew point comfort scale matches the gauge on the calculator:
| Dew point | Feels |
|---|---|
| Below 0 °C (32 °F) | Very dry |
| 0 to 10 °C (32 to 50 °F) | Dry |
| 10 to 13 °C (50 to 55 °F) | Comfortable |
| 13 to 16 °C (55 to 61 °F) | Pleasant |
| 16 to 18 °C (61 to 64 °F) | Slightly humid |
| 18 to 21 °C (64 to 70 °F) | Humid |
| 21 to 24 °C (70 to 75 °F) | Very humid |
| 24 °C (75 °F) and above | Oppressive |
What dew point is considered high? Anything over about 18 °C (65 °F) feels humid to most people, and over 24 °C (75 °F) feels oppressive. The dew point decides what the air feels like more than the temperature reading does.
Indoors, aim for a dew point below about 13 °C (55 °F) in summer. ASHRAE Standard 55, the HVAC comfort standard, sets an upper humidity ratio of 0.012, which is a dew point of about 16.8 °C (62 °F) at sea level. Higher indoor dew points raise the risk of condensation on cold surfaces and mold.
A dew point calculator works from temperature and humidity readings, so its answer is only as good as the instrument behind them. These are the main ways to measure dew point directly or indirectly.
| Instrument | How it works | Typical accuracy | Where it's used |
|---|---|---|---|
| Chilled mirror hygrometer | Cools a mirror until dew or frost forms and measures that temperature | ±0.1–0.2 °C | Reference and calibration labs |
| Capacitive humidity sensor | A polymer film changes capacitance with RH; dew point is calculated | ±1.5–3% RH | Weather stations, HVAC, handheld hygrometers |
| Aluminium or ceramic oxide sensor | Measures trace water in dry gas | ±2–3 °C dew point | Compressed air, natural gas, process gas |
| Sling psychrometer | Wet and dry bulb thermometers; dew point from the psychrometer equation | ±2–5% RH | Field checks, coating inspection |
Sensors drift, so calibration matters. Labs check hygrometers against a chilled mirror reference traceable to national standards. To work from wet and dry bulb readings, use the Dew point calculator wet bulb dry bulb.
Meteorologists watch the dew point because it shows the moisture available to the atmosphere. On a clear, calm night the temperature often falls only a little below the evening dew point, so it is a good first guess for the overnight low. When the temperature–dew point spread shrinks to 2–3 °C, fog and low cloud become likely, which is why aviation weather reports list both values. High dew points also fuel thunderstorms: forecasters look for rich low-level moisture before severe weather. And the height where rising air reaches its dew point sets the cloud base; try the Dew point cloud base calculation.
Many practical jobs come down to keeping the dew point in the right range. These common targets are a starting point; follow the equipment or product guidance where it is stricter.
| Space or job | Typical target | Matching dew point | Calculator |
|---|---|---|---|
| Living space in summer | Dew point under 13 °C (55 °F) | Below 13 °C | Dew point comfort calculator |
| Crawl space (encapsulated) | RH under 60% at about 18 °C | Below 10.1 °C | Dew point calculator mold risk |
| Wine cellar | 13 °C (55 °F), 60–70% RH | 5.4 to 7.7 °C | Dew point calculator relative humidity |
| 3D printing filament storage | RH under about 20% at 21 °C | Below −2.8 °C | Dew point vs absolute humidity calculator |
| Greenhouse, vegetative growth | VPD 0.8–1.2 kPa at 24 °C | 15.7 to 18.9 °C | VPD to dew point calculator |
| HVAC ducts and cold pipes | Surface above the room dew point | Depends on room air | Window dew point calculator |
| Industrial drying, compressed air | Pressure dew point −40 °C or lower | −40 °C at line pressure | Dew point calculator compressed air |
Sources
A free app from Alpha Moisture Systems for its SADPmini2 hygrometers. It calculates pressure dew points and converts between units such as ppm(V), saturated vapour pressure, lb/MMSCF and mg/m³ (App Store). Over Bluetooth it shows live readings from the instrument on a phone or tablet (source).
Portable meters take spot-check readings on compressed air lines, dryers and gas cylinders. Shaw's SADP, for example, gives a result in a few minutes and calibrates itself with an AutoCal function (source). Enter the reading in the trace moisture calculator to get the pressure dew point and ppm.
A hand held hygrometer reads air temperature and relative humidity, and many show the dew point too. It suits buildings, painting jobs, warehouses and HVAC checks. For dry process gas below about −20 °C dew point, use a dedicated dew point meter instead.
Trace moisture analysers measure very low water content, down to a few ppm(v), in compressed air, natural gas and process gases. They are fixed in place and run continuously, with alarms and outputs to a control system.
A sample system brings gas from the process line to the sensor at the right pressure and flow. It usually has an isolation valve, a filter, a pressure regulator or needle valve and a flowmeter. Leaks and wet tubing give false high readings, so stainless steel or PTFE tubing is the norm.
The sensor is the part that touches the gas. Inline sensors and transmitters send the dew point to a PLC or SCADA system, for example over 4–20 mA or Modbus RTU (source).
Sensors drift with age and contamination. Regular calibration against a reference hygrometer keeps readings trustworthy. Manufacturers such as Shaw service and calibrate their own dew point meters, hygrometers and analysers (source); check your instrument's manual for the interval.
Temperature moves all day, but the dew point tells you what the air is really carrying. Use this free online dew point calculator whenever conditions change: enter air temperature and relative humidity, read the dew point, and check the comfort label, the spread and the condensation check. For compressed air and gas, switch to the trace moisture calculator for pressure dew point and ppm. A quick check before you paint, pour, store or ship can save a wet surprise.
Each calculator below is built for one job and shows a live preview. Drag the slider on any card to see its result change, then open the full tool.
Calculate relative humidity from temperature and dew point, or dew point from RH.
Open calculatorFree dew point calculator in Fahrenheit.
Open calculatorMetric dew point calculator in Celsius.
Open calculatorCalculate dew point and relative humidity from wet bulb and dry bulb temperatures, with pressure correction.
Open calculatorCalculate dew point, mixing ratio and station pressure at any altitude.
Open calculatorCalculate frost point and dew point from temperature and humidity.
Open calculatorThe dew point formula explained with a step-by-step calculator.
Open calculatorFree dew point chart in Celsius and Fahrenheit.
Open calculatorFind dew point on an interactive psychrometric chart.
Open calculatorFind out how humid the air feels.
Open calculatorCalculate the temperature–dew point spread (dew point depression), fog risk and cumulus cloud base in metres and feet.
Open calculatorAdjust your running pace for heat and humidity.
Open calculatorFind where the dew point falls in your wall assembly.
Open calculatorCheck where the dew point falls in a warm flat roof, cold flat roof or pitched roof.
Open calculatorCheck mold and condensation risk on cold walls, windows and corners.
Open calculatorCheck if a surface is ready to paint.
Open calculatorConvert dew point from one pressure to another.
Open calculatorCheck compressed air dryness.
Open calculatorConvert dew point or frost point to ppm by volume and ppm by weight for air, nitrogen, hydrogen, CO₂, SF₆ and natural gas at any pressure.
Open calculatorConvert between dew point and absolute humidity in g/m³, mixing ratio in g/kg and grains per pound.
Open calculatorConvert natural gas water dew point to water content in lb/MMSCF, mg/Sm³ and ppmv at pipeline pressure (Bukacek).
Open calculatorEstimate natural gas hydrocarbon dew point (HCDP) from composition and pressure.
Open calculatorCalculate the water dew point of any gas mixture from composition, moisture and pressure.
Open calculatorConvert SF₆ moisture between ppmv, ppmw and dew point at atmospheric and filling pressure for GIS switchgear, breakers and gas-insulated transformers..
Open calculatorCalculate sulfuric acid (SO₃) and hydrochloric acid dew points of flue gas from water vapour, SO₃ and HCl.
Open calculatorDew point heat index calculator: enter temperature and dew point to get the heat index (feels-like temperature) in °F and °C with the NWS danger category..
Open calculatorApparatus dew point temperature calculator for cooling coils: find ADP, bypass factor, contact factor and sensible heat ratio from entering and leaving air..
Open calculatorVPD to dew point calculator for greenhouses and grow rooms: convert target vapour pressure deficit and air temperature to dew point and RH, with leaf VPD..
Open calculatorWindow dew point calculator: find the inner glass temperature, indoor dew point and the highest humidity before windows fog up, for single, double and triple glazing..
Open calculatorInstrument air dew point calculator: check your pressure dew point against the ISA-7.0.01 rule (10 °C below minimum ambient, max +4 °C), with ppm and ISO 8573-1 class..
Open calculatorFlue gas dew point calculator: water vapour dew point of flue gas from fuel type and O₂, for natural gas, propane, oil, wood pellets and coal..
Open calculatorHydrogen dew point calculator: convert water in hydrogen between ppmv, ppmw and dew point at any pressure, and check ISO 14687 fuel cell grade limits..
Open calculatorNitrogen dew point calculator: convert nitrogen dew point to ppmv and ppmw, find the pressure dew point at delivery pressure, and compare membrane, PSA and liquid nitrogen..
Open calculatorCO2 dew point calculator: convert water in carbon dioxide between ppmv, ppmw and dew point at pressure, and check the ISBT beverage-grade 20 ppm limit..
Open calculatorDew point vacuum calculator: water boiling and sublimation temperature at any vacuum pressure in mbar, Pa or Torr, and the dew point of air pumped down to vacuum..
Open calculatorDew point to grains calculator: convert dew point (°F) to grains of moisture per pound of dry air, g/kg and lb/lb, with elevation correction and ASHRAE 55 limit..
Open calculatorDew point vapor pressure calculator: actual and saturation vapour pressure from temperature and dew point in hPa, kPa, mmHg, inHg and psi, plus VPD and RH..
Open calculatorDew point cloud base calculation: estimate cumulus cloud base height in metres and feet from temperature and dew point, above ground and above sea level..
Open calculator35 °C (95 °F), at Dhahran, Saudi Arabia, on 8 July 2003. The air temperature was 42 °C (108 °F) at the time (NOAA). The dew point can never be higher than the air temperature, so a dew point this high needs extreme heat and a warm sea nearby.
Enter the air temperature and relative humidity in the calculator above and read the result. To work it by hand, use the Magnus formula in How to Calculate Dew Point. Example: 25 °C and 60% gives 16.7 °C.
At home, read the temperature and relative humidity from a digital hygrometer, then enter both here. Weather stations do the same. For compressed air and process gas, use a dew point meter or hygrometer with a sensor in the gas line, which reads the dew point directly, often well below −40 °C.
A 70 °F (21 °C) dew point means very humid air. Most people find it sticky and uncomfortable, and sweat dries slowly. So yes, a 70 dew point is high. In this kind of air, any surface cooler than 70 °F, such as an air-conditioned window, will sweat.
Much less than temperature does. It changes when the air mass changes: a sea breeze, a front, rain or plants releasing water can move it a few degrees. Relative humidity swings far more.
It tells you how muggy the air will feel, whether fog or frost will form overnight, and whether walls, windows and pipes will collect water. In industry it shows whether compressed air or gas is dry enough to use.
Yes. Weather forecasts give the dew point hour by hour. This calculator works out the current dew point from conditions you enter; it does not forecast.
Weather apps and national weather service observations list it next to temperature and humidity. Or take the temperature and humidity from a home weather station and use this calculator.
Both are temperatures where vapour leaves the air. Above 0 °C it condenses as liquid: the dew point. Below 0 °C it can deposit straight onto surfaces as ice: the frost point. The frost point sits slightly above the dew point. At −5 °C and 80% RH, for example, the dew point is −7.9 °C and the frost point is −7.0 °C.
Hardly. The dew point you calculate from temperature and relative humidity does not depend on air pressure. Altitude changes the mixing ratio, the grams of water per kilogram of air, which this page works out at sea-level pressure.
You don't need one. This page works in any phone browser. Add it to your home screen and it opens like an app.
Yes. It is free and needs no sign-up.
They use different equations for saturation vapour pressure, and some correct for gas pressure while others don't. Results usually differ by a few tenths of a degree. This one uses the Buck (1996) equations.