Acid gas dew point calculator
Acid condenses from flue gas far above the water dew point and corrodes air heaters, economisers, ducts and stacks. Enter the water vapour, SO₃ and HCl content to get each acid dew point and the minimum metal temperature.
Flue gas acid dew points
Move a slider or type a value. Results and the chart update as you go.
How acid gas dew point calculator works?
To calculate acid dew points, the calculator converts water vapour, sulfur trioxide (SO₃) and hydrogen chloride (HCl) to partial pressures in mmHg, then applies the Verhoff–Banchero and Kiang equations. It returns the sulfuric acid, hydrochloric acid and water dew points.
- It converts each component to a partial pressure in mmHg from its concentration and the flue gas pressure.
- Sulfuric acid: Verhoff and Banchero, 1000/T = 2.276 − 0.0294 ln(pH₂O) − 0.0858 ln(pSO₃) + 0.0062 ln(pH₂O) ln(pSO₃), T in K.
- Hydrochloric acid: Kiang, 1000/T = 3.7368 − 0.1591 ln(pH₂O) − 0.0326 ln(pHCl) + 0.00269 ln(pH₂O) ln(pHCl).
- The highest dew point governs. Keep metal surfaces 10–20 °C above it.
Acid gas dew point calculator formula
The Verhoff–Banchero equation is 1000/T = 2.276 − 0.0294 ln pH₂O − 0.0858 ln pSO₃ + 0.0062 ln pH₂O · ln pSO₃. The Kiang equation is 1000/T = 3.7368 − 0.1591 ln pH₂O − 0.0326 ln pHCl + 0.00269 ln pH₂O · ln pHCl. Pressures are in mmHg and T in kelvin.
- pH₂O water vapour partial pressure, mmHg (760 mmHg = 1 atm = 101.3 kPa)
- pSO₃ sulfur trioxide partial pressure, mmHg
- pHCl hydrogen chloride partial pressure, mmHg
- T acid dew point, K (°C = K − 273.15)
Acid gas dew point calculator conversion chart
Sulfuric acid dew point (Verhoff–Banchero) by SO₃ content and water vapour content, at atmospheric pressure.
| SO₃ | 5% H₂O | 8% H₂O | 10% H₂O | 12% H₂O | 15% H₂O | 20% H₂O |
|---|---|---|---|---|---|---|
| 1 ppm | 108 | 113 | 116 | 118 | 120 | 124 |
| 2 ppm | 115 | 120 | 122 | 124 | 126 | 130 |
| 5 ppm | 123 | 128 | 131 | 132 | 135 | 138 |
| 10 ppm | 130 | 135 | 137 | 139 | 141 | 144 |
| 20 ppm | 138 | 142 | 144 | 146 | 148 | 151 |
| 50 ppm | 148 | 152 | 154 | 156 | 158 | 160 |
Flue gas acid dew points by fuel
| Fuel | Typical SO₃ | Typical acid dew point |
|---|---|---|
| Natural gas | Near zero | Near water dew point, about 55–60 °C |
| Light fuel oil | 1–5 ppm | About 110–130 °C |
| Coal (medium sulfur) | 5–30 ppm | About 120–150 °C |
| Heavy fuel oil | 10–40 ppm | About 130–160 °C |
Avoiding acid dew point corrosion
- Keep cold-end metal temperatures above the acid dew point, with margin, at the lowest load.
- Preheat combustion air with steam coils or recirculation in cold weather.
- Use corrosion-resistant materials (enamelled elements, Corten-type or acid-resistant steels) where cooling below the dew point can’t be avoided.
Acid dew point equations and sources
Sulfuric acid: Verhoff and Banchero (1974). Hydrochloric acid: Kiang (1981). Both use partial pressures in mmHg and give T in kelvin; the calculator converts from vol% and ppm for you.
Sulfuric acid dew point table
| SO₃ | 5% H₂O | 8% | 10% | 12% | 15% | 20% |
|---|---|---|---|---|---|---|
| 1 ppm | 108 | 113 | 116 | 118 | 120 | 124 |
| 2 ppm | 115 | 120 | 122 | 124 | 126 | 130 |
| 5 ppm | 123 | 128 | 131 | 132 | 135 | 138 |
| 10 ppm | 130 | 135 | 137 | 139 | 141 | 144 |
| 20 ppm | 138 | 142 | 144 | 146 | 148 | 151 |
| 50 ppm | 148 | 152 | 154 | 156 | 158 | 160 |
Water vs sulfuric vs hydrochloric acid dew point
| Water dew point | H₂SO₄ dew point | HCl dew point | |
|---|---|---|---|
| Typical range | 40–60 °C | 110–160 °C | 50–80 °C |
| Driven by | Water vapour | SO₃ + water | HCl + water |
| Main risk | Wet stacks, condensate | Severe cold-end corrosion | Corrosion in waste-to-energy plants |
Acid gas dew point calculator FAQs
What is acid dew point?
The temperature at which acid, mainly sulfuric acid, starts to condense from flue gas. For sulfur-bearing fuels it is typically 110–150 °C, far above the water dew point.
How do you calculate sulfuric acid dew point?
With the Verhoff–Banchero equation: 1000/T = 2.276 − 0.0294 ln(pH₂O) − 0.0858 ln(pSO₃) + 0.0062 ln(pH₂O)·ln(pSO₃), pressures in mmHg and T in K. With 12% water and 5 ppm SO₃ that gives about 132 °C.
How do you calculate HCl dew point?
With the Kiang equation: 1000/T = 3.7368 − 0.1591 ln(pH₂O) − 0.0326 ln(pHCl) + 0.00269 ln(pH₂O)·ln(pHCl). At 10% water and 50 ppm HCl it's about 48 °C.
What's the difference between SO₂ and SO₃ dew points?
SO₃ forms sulfuric acid with a high dew point. SO₂ forms sulfurous acid with a dew point near the water dew point. Only 1–5% of fuel sulfur usually becomes SO₃, but it sets the acid dew point.
What is the flue gas dew point for natural gas?
With almost no sulfur, natural gas flue gas condenses near the water dew point, about 55–60 °C, which condensing boilers exploit.
How much margin above acid dew point is needed?
Designers commonly keep the coldest metal 10–20 °C above the acid dew point at minimum load.
How accurate is Verhoff–Banchero?
It's the most widely used correlation, but it can overpredict at high moisture (above about 15% water). Treat it as conservative there.
How do I find SO₃ concentration?
Measure with a controlled condensation method or estimate from fuel sulfur and a conversion rate (typically 1–5%).
What is the Verhoff–Banchero equation?
The Verhoff–Banchero equation is 1000/T = 2.276 − 0.0294 ln pH₂O − 0.0858 ln pSO₃ + 0.0062 ln pH₂O ln pSO₃, published in 1974 for sulfuric acid dew point.
What is the acid dew point with 10% water and 10 ppm SO₃?
10% water vapour and 10 ppm SO₃ give a sulfuric acid dew point of about 137 °C (279 °F).
What margin above acid dew point is used?
Boiler designers keep the coldest metal 10–20 °C (18–36 °F) above the acid dew point at minimum load.