Choose your glazing and enter indoor and outdoor conditions. The calculator works out the inner glass temperature from its U-value, compares it with the indoor dew point, and tells you the highest humidity you can keep before condensation forms.

Will my windows condense?

Move a slider or type a value. Results and the chart update as you go.

°C
%
°C

How window dew point calculator works?

To check window condensation, the calculator estimates the inner glass temperature from the glazing U-value and the indoor and outdoor temperatures, then compares it with the indoor dew point. It returns the highest indoor relative humidity (RH) the glass can take before it mists up.

  1. It calculates the indoor dew point from room temperature and humidity.
  2. The inner glass temperature is Ts = Tin − U × Rsi × (Tin − Tout), with Rsi = 0.13 m²K/W.
  3. If Ts is at or below the dew point, condensation forms on the room side.
  4. The highest safe RH is 100 × es(Ts) ÷ es(Tin).

Window dew point calculator formula

The inner glass temperature is Ts = Tin − U × Rsi × (Tin − Tout), with Rsi = 0.13 m²K/W. Condensation forms when Ts ≤ Td. The highest safe RH is 100 × es(Ts) ÷ es(Tin).

Window dew point calculator conversion chart

Highest indoor RH at 20 °C before the centre of the glass reaches the dew point.

Maximum indoor RH before window condensation: Maximum indoor RH (%) by glazing and outdoor temperature
Outdoor tempSingle (U 5.8)Double (U 2.8)Double low-E (U 1.4)Triple (U 0.8)
10 °C62%80%89%94%
5 °C48%71%84%91%
0 °C37%63%80%88%
−5 °C28%56%75%85%
−10 °C22%49%71%82%
−20 °C12%38%63%77%
−30 °C7%30%56%72%

Glass temperature by glazing type

Better glazing keeps the inner pane closer to room temperature, well above the dew point.

Maximum indoor humidity vs outdoor temperature

The colder it gets outside, the lower the humidity your windows can tolerate.

Fixing window condensation

Fix Effect
Run extractor fans, ventilate briefly Lowers indoor dew point
Open curtains and blinds at night Lets room air warm the glass
Fit warm-edge spacers or secondary glazing Raises edge and glass temperature
Upgrade to low-E double or triple glazing Raises glass temperature permanently

Window dew point calculator FAQs

Why do my windows condense on the inside?

The glass is colder than the dew point of the room air. It happens with high indoor humidity, cold weather and poorly insulating glazing.

What humidity stops window condensation?

It depends on the glazing and outdoor temperature. With double glazing at −5 °C outside and 20 °C inside, keep RH below about 56%.

Does condensation between panes mean the same thing?

No. Condensation between panes means the sealed unit has failed and needs replacing; this calculator covers the room-side surface.

Is condensation on the outside of windows a problem?

No. Exterior condensation on clear mornings shows the glass is well insulated and cold on the outside.

Why do the edges condense first?

Frames and spacer bars conduct more heat than the centre of the glass, so edges run colder. Warm-edge spacers help.

What U-value should I use?

Use the centre-of-glass U-value from the manufacturer: about 5.8 for single, 2.8 for old double, 1.1–1.4 for low-E double and 0.5–0.8 for triple glazing.

What is the formula for inner glass temperature?

The formula is Ts = Tin − U × 0.13 × (Tin − Tout), with the U-value in W/m²K.

At what humidity does double glazing condense at 0 °C outside?

Double glazing (U 2.8) at 0 °C (32 °F) outside and 20 °C (68 °F) inside condenses above about 63% indoor RH.

Does triple glazing stop condensation?

Yes, on the centre of the glass in almost all homes: triple glazing (U 0.8) stays dry up to about 82% indoor RH at 20 °C inside and −10 °C (14 °F) outside.