Dew point calculator compressed air
Enter your pressure dew point, line pressure and flow. The calculator gives the ISO 8573-1 water class, the dew point at atmospheric pressure, the moisture in ppm and how much water your air still carries every day.
Rate your compressed air
Move a slider or type a value. Results and the chart update as you go.
How dew point calculator compressed air works?
To rate compressed air dryness, the calculator converts your pressure dew point (PDP) at line pressure into ppm by volume, the atmospheric dew point and kilograms of water per day, then assigns the ISO 8573-1 water class.
- It converts the pressure dew point at your line pressure into a water mole fraction (ppm by volume).
- It finds the dew point the same air would have at atmospheric pressure, for comparison with portable meters.
- It looks up the ISO 8573-1 water vapour class: class 1 at −70 °C or drier, down to class 6 at +10 °C.
- It estimates the water still in the air: ppm × flow, in kg per day.
Dew point calculator compressed air formula
The compressed air method is x = f·es(PDP) ÷ p; water carried is x × flow ÷ 22.414 × 18.015 × 24 g/day with flow in Nm³/h. ISO 8573-1 classes: 1 ≤ −70 °C, 2 ≤ −40 °C, 3 ≤ −20 °C, 4 ≤ +3 °C, 5 ≤ +7 °C, 6 ≤ +10 °C. John Dalton's law of partial pressures (1801) underpins the method: water vapour keeps its own share of the total pressure, so its partial pressure is the mole fraction times the absolute pressure.
- PDP pressure dew point, °C
- p absolute line pressure, bar a (barg + 1.013)
- x water mole fraction
- flow air flow, Nm³/h (1 Nm³/h ≈ 0.62 scfm)
- ADP atmospheric dew point, °C
Dew point calculator compressed air conversion chart
Compressed air classes by pressure dew point, with the matching atmospheric dew point and moisture at 7 barg.
| Class | Pressure dew point | Atmospheric dew point (7 barg) | Moisture (ppm v) | Typical dryer |
|---|---|---|---|---|
| Class 1 | ≤ −70 °C | −82.9 °C | 0.338 | Desiccant, −70 °C |
| Class 2 | ≤ −40 °C | −56.7 °C | 16.6 | Desiccant, −40 °C |
| Class 3 | ≤ −20 °C | −39.6 °C | 133 | Desiccant or membrane |
| Class 4 | ≤ 3 °C | −20.5 °C | 973 | Refrigerated |
| Class 5 | ≤ 7 °C | −17.6 °C | 1,286 | Refrigerated |
| Class 6 | ≤ 10 °C | −15.4 °C | 1,576 | Refrigerated |
Choosing a dryer by dew point
| Dryer | Typical pressure dew point | Running cost | Use |
|---|---|---|---|
| Refrigerated | +3 to +7 °C | Low | General plant air indoors |
| Membrane | +15 to −40 °C | Medium (purge) | Point of use, small flows |
| Heatless desiccant | −40 or −70 °C | High (15–20% purge) | Instruments, outdoor lines |
| Heated / blower purge desiccant | −40 °C | Medium | Large flows |
How much water does compressed air carry?
Air entering a compressor at 25 °C and 70% RH carries about 16.1 g of water per cubic metre. Aftercoolers and dryers remove almost all of it; the rest is set by the pressure dew point.
Measuring compressed air dew point
Install the sensor at line pressure, use stainless steel or PTFE tubing, and purge until the reading is stable. Nylon and polyurethane tubing absorb water and make readings slow and wet.
ISO 8573-1 water classes at 7 barg
| Class | Max pressure dew point | Atmospheric dew point | Moisture ppm(v) |
|---|---|---|---|
| 1 | −70 °C | −82.9 °C | 0.338 |
| 2 | −40 °C | −56.7 °C | 16.6 |
| 3 | −20 °C | −39.6 °C | 133 |
| 4 | 3 °C | −20.5 °C | 973 |
| 5 | 7 °C | −17.6 °C | 1,286 |
| 6 | 10 °C | −15.4 °C | 1,576 |
Common compressed air specifications
| Application | Typical ISO 8573-1 class [particles:water:oil] | Water class |
|---|---|---|
| General workshop | [3:4:3] | 4 (+3 °C) |
| Spray painting | [1:4:1] or [1:2:1] | 4 or 2 |
| Food and beverage contact | [1:2:1] | 2 (−40 °C) |
| Instrument air | [1:2:1] typical | 2 |
| Electronics, pharma | [1:1:1] | 1 (−70 °C) |
Dew point calculator compressed air FAQs
What dew point should compressed air be?
For general plant air indoors, a +3 °C pressure dew point from a refrigerated dryer (ISO 8573-1 class 4) is usually enough. For outdoor lines, instrument air, food and pharmaceutical use, −40 °C (class 2) or drier is typical.
What are the ISO 8573-1 water classes?
Class 1: ≤ −70 °C PDP; class 2: ≤ −40 °C; class 3: ≤ −20 °C; class 4: ≤ +3 °C; class 5: ≤ +7 °C; class 6: ≤ +10 °C. Class 0 is set by the user and stricter than class 1.
What is the dew point of compressed air at 7 bar?
It depends on the dryer, not the pressure: about +3 °C with a refrigerated dryer, −40 °C or −70 °C with a desiccant dryer.
What is instrument air dew point?
ISA-7.0.01 asks for a pressure dew point at least 10 °C (18 °F) below the lowest ambient temperature the air lines are exposed to, and never above +4 °C.
Why does my compressed air have water in it?
Somewhere the air is cooled below its pressure dew point: lines running outdoors or through cold spaces, a failed dryer or blocked drains.
Refrigerated or desiccant dryer?
Refrigerated dryers reach about +3 °C PDP and are cheap to run. Desiccant dryers reach −40 °C or −70 °C but use purge air or heat. Pick the warmest dew point that keeps your lines dry.
How do I measure compressed air dew point?
With a dew point sensor rated for line pressure, installed inline or in a sampling cell. Purge the sample line first; wet tubing gives high readings.
Does lower dew point cost more energy?
Yes. Going from +3 °C to −40 °C typically means a desiccant dryer using 15–20% of the air for purge (heatless type), or heated regeneration.
What is the ISO 8573-1 class for a −40 °C pressure dew point?
A −40 °C (−40 °F) pressure dew point is ISO 8573-1 class 2 for water vapour.
How do you calculate water in compressed air?
Water in compressed air is the mole fraction x = f·es(PDP) ÷ p times the molar flow; 500 Nm³/h at a +3 °C PDP and 7 barg carries about 9.4 kg (20.7 lb) of water a day.
What is a refrigerated dryer's pressure dew point in Fahrenheit?
A refrigerated dryer's pressure dew point is about +3 °C, which is 37–38 °F (ISO 8573-1 class 4).