Skip to content

Hydrocarbon dew point calculator

Enter a natural gas composition, C1 to C7+ with nitrogen and CO₂, and a pressure up to 40 bar. The calculator estimates the hydrocarbon dew point and draws the low-pressure branch of the dew curve.

Estimate the hydrocarbon dew point

Move a slider or type a value. Results and the chart update as you go.

mol%
mol%
mol%
mol%
mol%
mol%
mol%
mol%
mol%
mol%
mol%
bar a

How hydrocarbon dew point calculator works?

To estimate hydrocarbon dew point (HCDP), the calculator normalises your gas composition, estimates a vapour–liquid ratio (K-value) for each component with the Wilson equation, and solves for the temperature where the first drop of liquid forms at your pressure.

  1. It normalises your composition to 100 mol%.
  2. For each component it estimates a K-value (vapour/liquid ratio) with the Wilson equation from critical temperature, critical pressure and acentric factor.
  3. At the dew point the first drop of liquid forms, where the sum of yi/Ki equals 1. It solves for that temperature at your pressure.
  4. It repeats from 1 to 40 bar to draw the low-pressure branch of the dew curve. Higher pressures need an equation of state.

Hydrocarbon dew point calculator formula

The Wilson K-value is Kᵢ = (Pcᵢ ÷ P) × exp[5.373 × (1 + ωᵢ) × (1 − Tcᵢ ÷ T)]. The dew point condition is Σ yᵢ ÷ Kᵢ = 1. Tc and Pc are critical temperature and pressure; ω is the acentric factor.

Hydrocarbon dew point calculator conversion chart

Estimated hydrocarbon dew point (Wilson K-values) of the default lean gas, a very lean gas and a rich gas at pressures up to 40 bar a.

Hydrocarbon dew point by pressure: Hydrocarbon dew point (°C) by pressure and gas richness
PressureVery lean gasDefault lean gasRich gas
2 bar a (29 psia)−56−37−16
5 bar a (73 psia)−40−212
10 bar a (145 psia)−26−618
15 bar a (218 psia)−17329
20 bar a (290 psia)−101137
30 bar a (435 psia)12249
40 bar a (580 psia)103059

Example dew curve

Pressure HCDP (default lean gas)
2 bar a −36.8 °C
5 bar a −20.5 °C
10 bar a −6.2 °C
20 bar a 10.5 °C
30 bar a 21.7 °C

Controlling hydrocarbon dew point

Method How it works Typical use
Joule-Thomson valve Expansion cools gas, heavy ends condense Simple plants, high inlet pressure
Mechanical refrigeration Chiller cools gas to about −20 to −30 °C Most HCDP control units
Turbo-expander Expansion with work recovery, very cold NGL recovery plants
Short-cycle adsorption Silica gel removes heavy ends and water Offshore, small flows

Why this is a screening estimate

Phase behaviour near the dew curve is very sensitive to the heaviest components and how C6+ is characterised. Studies show different calculation methods can disagree by several degrees, so tune equations of state to measured dew points for contract work.

HCDP methods compared

Method Accuracy Speed Cost
Wilson K-values (this tool) Screening Instant Free
EOS from C6+ GC Good if tuned Minutes Software + GC
EOS from C9+ GC Better Minutes Extended GC
Chilled-mirror measurement Reference Minutes per point Instrument

Hydrocarbon dew point calculator FAQs

What is hydrocarbon dew point?

The temperature, at a given pressure, at which heavier hydrocarbons in natural gas start to condense as liquid.

What is the cricondentherm?

The highest temperature on the phase envelope's dew curve. Above it, no liquid can form at any pressure. Many contracts specify a cricondentherm hydrocarbon dew point.

How is hydrocarbon dew point calculated?

From a gas chromatograph analysis and an equation of state such as Peng-Robinson or SRK. ISO 23874 sets the chromatograph requirements for this.

Which components affect hydrocarbon dew point most?

The heaviest ones. A few hundred ppm of C7+ raises the dew point more than several percent of propane.

How accurate is this calculator?

It's a screening estimate using Wilson K-values, good for comparing compositions at low to moderate pressure. It can't find the cricondentherm and isn't for custody transfer.

How is HCDP measured?

With chilled-mirror instruments (manual or automatic), or calculated from an extended C9+ chromatograph analysis.

What is a typical HCDP specification?

It varies by pipeline; many specify a cricondentherm of about −2 °C to +5 °C, or a dew point at a stated pressure.

Is there a hydrocarbon dew point calculator in Excel?

Yes, the Wilson method fits in a spreadsheet, but for contract work use proper equation-of-state software or measurement.

What is the Wilson equation for K-values?

The Wilson equation is K = (Pc ÷ P) × exp[5.373 × (1 + ω) × (1 − Tc ÷ T)], an ideal-mixture estimate of vapour/liquid ratios.

What is the HCDP of a lean gas at 20 bar?

The default lean gas on this page has an estimated HCDP of 11 °C (51 °F) at 20 bar a (290 psia).

Which equation of state is used for contract HCDP?

Peng-Robinson (1976) and Soave-Redlich-Kwong (1972) equations of state, tuned to a detailed C6+ or C9+ analysis, are used for contract HCDP calculations.