Skip to content

Instrument air dew point calculator

Enter the lowest ambient temperature your instrument air lines see, your measured pressure dew point and line pressure. The calculator applies the ISA-7.0.01 rule and shows pass or fail, the margin, the atmospheric dew point and the ISO 8573-1 class.

Check instrument air dryness

Move a slider or type a value. Results and the chart update as you go.

°C
°C
barg

How instrument air dew point calculator works?

To check instrument air, the calculator sets the required pressure dew point (PDP) at 10 °C (18 °F) below your lowest ambient temperature, caps it at +4 °C (39 °F), and compares your reading. It converts the reading to ppm and the ISO 8573-1 class.

  1. It sets the required pressure dew point to 10 °C below the lowest ambient temperature.
  2. It caps the requirement at +4 °C (39 °F), as ISA-7.0.01 specifies.
  3. It compares your measured pressure dew point and gives the margin.
  4. It converts to ppm(v) and the atmospheric dew point for comparison with portable meters.

Instrument air dew point calculator formula

The instrument air rule from ISA-7.0.01 is PDP ≤ min(T ambient − 10 °C, +4 °C). The moisture conversion is x = f·es(PDP) ÷ p. John Dalton's law of partial pressures (1801) underpins the method: water vapour keeps its own share of the total pressure, so its partial pressure is the mole fraction times the absolute pressure.

Instrument air dew point calculator conversion chart

Maximum pressure dew point by lowest ambient temperature (ISA-7.0.01), with the equivalent at atmospheric pressure from a 7 barg line.

Required instrument air dew point: Required pressure dew point by lowest ambient temperature
Lowest ambientMax pressure dew pointAtmospheric equivalent (7 barg)Moisture ppm(v)
30 °C4 °C−19.8 °C1,044
15 °C4 °C−19.8 °C1,044
10 °C0 °C−22.7 °C784
0 °C−10 °C−31.1 °C335
−10 °C−20 °C−39.6 °C133
−20 °C−30 °C−48.1 °C49.1
−30 °C−40 °C−56.7 °C16.6
−40 °C−50 °C−65.4 °C5.08

Required pressure dew point vs ambient temperature

The requirement follows the coldest ambient temperature, so outdoor plants in cold climates need much drier air.

Converting your reading

Check which pressure your meter measures at before comparing with the requirement.

Instrument air vs plant air vs breathing air

Air type Typical dew point spec
Instrument air (ISA-7.0.01) 10 °C below lowest ambient, max +4 °C
General plant air +3 °C PDP (refrigerated dryer)
Breathing air (EN 12021) Dew point well below the lowest likely temperature

Instrument air dew point calculator FAQs

What dew point should instrument air have?

ISA-7.0.01 asks for a pressure dew point at least 10 °C (18 °F) below the lowest ambient temperature the air system sees, and never above +4 °C (39 °F).

Is instrument air dew point measured at line pressure?

Yes. The requirement is a pressure dew point at line pressure. A vented sample reads lower.

What dryer is used for instrument air?

Usually a desiccant dryer giving −40 °C pressure dew point, which covers lines down to −30 °C ambient.

What ISO 8573-1 class is instrument air?

Commonly class 2 for water (−40 °C PDP), though the class depends on site conditions.

Why does instrument air need to be so dry?

Water in instrument lines freezes in cold weather and corrodes valve positioners, transmitters and actuators.

What is the instrument air dew point formula?

The instrument air dew point formula is PDP ≤ min(lowest ambient − 10 °C, +4 °C), from ISA-7.0.01.

What dew point does instrument air need at −20 °C ambient?

Instrument air exposed to −20 °C (−4 °F) needs a pressure dew point of −30 °C (−22 °F) or lower.

What does ISA stand for?

ISA stands for the International Society of Automation, which publishes ISA-7.0.01, the quality standard for instrument air.