Skip to content

Dew point calculator nitrogen

Enter the dew point of your nitrogen at atmospheric pressure and the delivery pressure. The calculator gives the moisture in ppm(v) and ppm(w), the pressure dew point in the line and the typical source that reaches that dryness.

Nitrogen moisture and dew point

Move a slider or type a value. Results and the chart update as you go.

°C
barg

How dew point calculator nitrogen works?

To calculate nitrogen dew point, the calculator converts the atmospheric dew point into ppm by volume and by weight, then finds the pressure dew point at your delivery pressure. It shows which nitrogen source usually reaches that dryness.

  1. It converts the atmospheric dew point to a water mole fraction (frost point below 0 °C).
  2. It multiplies by one million for ppm(v) and converts to ppm(w) with nitrogen's molar mass, 28.013 g/mol.
  3. It finds the dew point at your delivery pressure.
  4. It shows where the value sits against typical nitrogen sources.

Dew point calculator nitrogen formula

The nitrogen dew point formulas are x = f·es(Td) ÷ 1.01325 bar, ppmw = ppmv × 18.015 ÷ 28.013 and f·es(PDP) = x × p. John Dalton's law of partial pressures (1801) underpins the method: water vapour keeps its own share of the total pressure, so its partial pressure is the mole fraction times the absolute pressure.

Dew point calculator nitrogen conversion chart

Moisture in nitrogen at common dew points, and the pressure dew point at 7 barg.

Nitrogen dew point conversion: Nitrogen dew point, ppm and pressure dew point
Dew point at 1 atmppm(v)ppm(w)Pressure dew point at 7 barg
−80 °C0.5440.35−66.8 °C
−70 °C2.61.67−55.3 °C
−60 °C10.76.9−43.8 °C
−50 °C39.125.1−32.2 °C
−40 °C12781.9−20.5 °C
−30 °C377242−8.7 °C
−20 °C1,0246593.7 °C

Nitrogen pressure dew point

The same nitrogen condenses at a higher temperature once it’s compressed for delivery.

Nitrogen moisture units

Different industries quote nitrogen dryness in different units; these all describe the same gas.

Nitrogen sources compared

Source Typical dew point at 1 atm Notes
Membrane generator −20 to −40 °C Simple, purity up to about 99.5%
PSA generator −40 to −70 °C Higher purity, dryer output
Liquid nitrogen / cylinders Below −70 °C Very dry; delivered product

Dew point calculator nitrogen FAQs

What is the dew point of nitrogen?

It depends on the source: membrane generators typically −20 to −40 °C, PSA generators −40 to −70 °C, and gas from liquid nitrogen often below −70 °C.

How do you convert nitrogen dew point to ppm?

Find the vapour pressure at the dew point and divide by the total pressure. −40 °C at 1 atm is about 127 ppm(v).

Why does nitrogen dew point matter?

Moisture causes oxidation in food packaging, electronics soldering and laser cutting, and can freeze in lines.

Is nitrogen dew point the same at pressure?

No. Compressing nitrogen raises its dew point; specify the pressure with the dew point.

How do I measure nitrogen dew point?

With a dew point transmitter at line pressure or a sampling cell, purged until stable.

What is the nitrogen dew point formula?

The nitrogen dew point formula is x = f·es(Td) ÷ p at atmospheric pressure, then f·es(PDP) = x × p at line pressure.

What is −70 °C nitrogen in ppm?

Nitrogen with a −70 °C (−94 °F) frost point holds 2.6 ppm(v) of water.

What is the molar mass of nitrogen?